Test RPC-GMT
|
Pattern Test
|
Setup
The clock and BC0 was distributed from a common TTCci/TTCex system.
Patterns were generated at the output of the RPC Final Sorter and transmitted on BC0 to GMT where they were read from InputFPGA spys using GMTINxSpyTest function of the gmt.exe program. Long term stability tests were performed using GMTInterfaceBitErrorTest function.
|
Results
The transmission of all patterns was correct. A 16h long-term tests showed no errors. This corresponds to more than 6x1013 bits transmitted without errors. |
|
|
|